Panels¶
A panel is a ready-made group of equipment, readouts and controls, already wired together: drop one and you have a complete pump control, well site or filter overview. Connect it to a device and it's done.
Use a panel¶
- In the catalog, open Panels (or App panels, or My panels) and drag one onto the drawing.
- Its settings open. On the Tags tab, pick the Device: every part of the panel is pointed at the channel with the same name on that device.
- Check the list of parts below it, and pick any tag that didn't match by hand.

- Device: changing it re-points every tag in the panel.
- Each part of the panel, with its own tags. You can still change any single tag.
On an account HMI a panel also has a Location. Pick another location and the panel moves there: if that location has one device, every tag moves to the channel with the same name on it; if it has several, the tags are cleared so you can pick each one (there's no safe way to guess which device each belongs to). The panel's title follows the location's name.
A panel moves, copies and deletes as one piece. Ungroup (Ctrl+Shift+G) breaks it into its parts if you want to rearrange them; Group as panel (Ctrl+G) puts parts back together.
The panels¶
| Panel | Shows |
|---|---|
| Pump control | A pump with Call, Running and Fault lights, a Mode (HOA) switch, its speed and a speed setpoint |
| Valve control | Opened and Closed lights and Open / Close buttons |
| Tank | A tank with its level and a Filling light |
| Lift station overview | A wet well with Pump 1, Pump 2, High level and On generator lights |
| Well site | A well: inline submersible pump, Station mode and HOA, speed, discharge pressure, runtime today and total, running and fault lights; Flow, Chlorine and the Pumped total are optional |
| Blower | Running and Fault lights, Mode switch, speed and speed setpoint, basin DO |
| Chemical feed | Feed rate and rate setpoint, Clâ‚‚ residual, pump running and fault lights |
| Filter overview | One filter without piping, for a screen of all the filters (see Filters) |
| Filters (common) | Total filtered flow, filters in service, raw water lockout, head loss, run hours, turbidity, and the head loss and turbidity backwash triggers |
| Backwash | The filter washing, the step and time left, flows and turbidity, the sequence and command switches, automatic starts, and the step times and flow setpoint |
Parts marked Optional (see the designer) are hidden in Run mode while they have no tag, so one panel serves wells with and without a flow meter or chlorine analyzer.
App panels¶
App panels match the D6 apps: SmartPump Duplex, SmartPump Triplex, SmartWell Single, SmartWell Multi master, SmartWell Multi well, Smart Lift, SmartMeter, SmartFlow, SmartLevel, Smart Tower and SmartLeak. Drop one and it finds the controller running that app by itself: each part links to the channel it's named for. If several devices have the app's channels, Which device? asks which one to link; if none does, pick the Device in the panel's Tags. Parts the controller has no channel for stay hidden, so the same panel fits every version of the app.
Your own panels¶
Build a group once and reuse it everywhere in your account:
- Select the parts and press Ctrl+G (Group as panel).
- Click Save as panel (in the Panel section of Properties, or Save as panel… on the right-click menu) and give it a name.
- It appears under My panels in the catalog, for everyone in your account who edits HMIs.
To remove a saved panel from My panels, contact D6 Labs support.
Upgrade panels¶
A panel is a copy of its template, made when you drop it. When D6 improves a panel (the Well site panel's new pump drawing and readouts, for example), panels already on your HMIs don't change by themselves. The designer tells you when there's something to upgrade:

- Upgrade panels (N) in the top bar: N panels on this HMI come from an older version of their template. (Also on the right-click menu of empty space.)
Click it, check the list in Upgrade panels and click Upgrade N. Every out-of-date panel is rebuilt in place with the current layout:
- its position, caption, caption size and location are kept;
- tags carry over by what they do: the old pump's running tag also feeds the new Running light;
- new parts link to the channel with the same name on the panel's device, where there is one;
- parts the template dropped are removed; parts you added yourself are kept.
Then a report shows, for each panel, the tags kept, linked by name, still to link and removed. Connect the still to link ones by hand. Ctrl+Z undoes the whole upgrade, and nothing is saved until you click Save.
Filters¶
A gravity filter has a connection point for every pipe it has, so you can draw the whole flow through it:
| Connection | Where on the filter |
|---|---|
| Influent | Top |
| Backwash waste | Upper right, from the wash trough |
| Effluent | Lower right, from the underdrain |
| Air scour | Lower left, into the underdrain |
| Backwash supply | Bottom left |
| Filter to waste | Bottom right |
The filter shows the step it's in: water moving down through the media in service and while filtering to waste, moving up while backwashing, and air bubbling through the media during air scour. Its label reads Backwash, Air scour or To waste during those steps, otherwise the level and head loss.
A filter takes either separate In service, Backwashing, Filtering to waste and Air scour tags, or one Filter state code: 0 Out of service, 1 Manual, 2 In service, 3 Backwash requested, 4 Backwashing, 5 Filter to waste, 6 Not ready, 7 Valve fault, 8 Backwash hold.
An overview screen of all the filters¶
The Filter overview panel shows one filter without its piping. Put one per filter on a screen to see all of them at once. It has:
- the filter, with its level and the step it's in;
- Level, Head loss, Flow and Turbidity;
- a Status label for the filter's step tag (change the list to match your controller's numbers in the label's States);
- a valve indicator for each valve: influent, effluent, filter to waste, backwash supply, backwash waste and air scour.
A valve indicator shows OPEN, CLOSED or MOVING (neither limit switch made) from the valve's Opened and Closed tags. The influent and effluent valves also have a Position tag: the indicator adds the position in % with a bar. Any one of the three tags is enough.